YEFRBG YGFRBG tensile flat cable

YEFRBG YGFRBG tensile flat cable features and uses
This product is mainly used for ladle cars with AC rated voltage of 0.6/1KV and below, steel mills, metallurgical enterprises and similar applications. The cable has good temperature resistance, corrosion resistance, aging resistance, softness, k type thermocouple anti-drag, splash-proof steel, long life and so on. Multi-core, multi-group multi-purpose combination cable with power, control and communication can be designed according to users and equipment needs.
Second, pt100 thermocouple implementation standardsQ/AT2005-8
Third, dual thermocouple the use of characteristics
1. The rated working voltage U0/U is 0.6/1KV;
2. The maximum allowable operating temperature of cable conductors is 90 ° C and 180 ° C;
3. When the cable is short-circuited (the longest time does not exceed 5S), the maximum working temperature is 250 °C;
4. The minimum bending radius of the cable is not less than 6 times the actual outer diameter of the cable.
Fourth, YEFRBG YGFRBG tensile flat cable the basic model and name

YEFRBG YGFRBG tensile flat cable Model Name Voltage Rating Nominal Cross Section (mm2)
(KV) power core control core
AnHui TianKang (Group)Shares Co.,Ltd YEFRBG copper core hybrid rubber insulated and anti-corrosion sheathed anti-cable flexible cable for ladle car 0.6/1 4–120 2.5–10
YGFRBG copper core high temperature resistant rubber insulated and anticorrosive sheathed steel flexible cable for electric vehicles 0.6/1 4–120 2.5–10
YVFRGNHP32 steel core copper conductor soft core structure nitrile insulated winding refractory layer braided stainless steel wire armored ladle combination cable 0.6/1 4–120 2.5–10
YGCFNHP32 steel core copper conductor soft core structure nitrile insulated winding refractory layer braided stainless steel wire armored ladle combination flat cable 0.6/1 4–120 2.5–10
YGCBNHP32 steel core copper conductor soft core structure silicone rubber insulated winding refractory layer braided stainless steel wire armored shielded combination flat cable 0.6/1 4–120 2.5–10
V. YEFRBG YGFRBG tensile flat cable Main technical indicators

Performance item target requirement unit indicator
armored thermocouple Conductor DC resistance in accordance with GB/T3956 standard Ω/KM
Power frequency withstand voltage test (AC 50HZ)
Power core 3.5/5 KV/min without breakdown
Control wire core 1.5/5 KV/min without breakdown
Insulation resistance constant at 0 °C
Mixed rubber ≥ 3670 MΩ × KM is greater than
High temperature rubber ≥ 1500 MΩ × KM is greater than
Flame retardant properties meet the requirements of GB/T18380-2001
Bending performance test 50000 times The core is not broken, the insulation is not cracked
Tensile strength 12 KN is greater than
Sixth,High temp thermocouple basic cable specifications and structural parameters

YEFRBG YGFRBG tensile flat cable Number of cores × nominal cross section of conductor (mm2) Nominal thickness mm Reference current carrying capacity A GB-YEFGBJR, GB-YGFGBJR
Power wire core Control wire core  Wear-resistant thermocouple Power core insulation sheath Cable outer diameter mm Approximate weight KG/KM
3×10 3×2.5 2 2.2 87 26.5—29.8 1988
3×16 3×2.5 2.2 2.2 120 31.6—34.7 2123
2×25 3×4 2.4 2.4 155 38.2—41.5 2845
3×35 3×4 2.8 2.4 185 42.1—46.8 3227
3×50 3×4 2.8 2.6 220 46.4—52.0 4171
3×70 3×6 3 2.8 270 52.7—59.0 5619
Surface Thermocouple 3×95 3×6 3 3 320 57.8—64.6 7634

Leave a Reply