First, Butadiene silicone flat cable product features and uses
The product is suitable for casting cranes, port machinery and trolley moving cables with AC rated voltage of 0.6/1KV and below. The product has the characteristics of high temperature resistance, cold resistance, oil resistance, anti-corrosion, etc. The cable structure is soft and flat, convenient to lay, stable in electrical performance under high temperature and cold environment, anti-aging, long service life, etc.,k type thermocouple widely used in metallurgy and electric power. , petroleum, chemical, port and mobile equipment manufacturing industries.
Second, product implementation standardsQ/AT2005-2
Third, Butadiene silicone flat cable use of characteristics
1. AC rated voltage: U0/U 0.6/1KV;
Maximum working temperature: 180 ° C;
Minimum ambient temperature: fixed laying -60 ° C;
2. The cable installation temperature is not below -25 °C.
Fourth, the basic model and name thermocouple probe
Butadiene silicone flat cable model
product name
YGDGB
Flat flexible cable for silicone rubber insulation and sheath movement
YDGCB-VFR
Nitrile insulated butadiene rubber sheathed flat flexible cable for mobile armored thermocouple
YDGCB-AF46R
F46 insulated silicone rubber sheathed flat flexible cable http://www.chinathermocouple.com
YDGCPB
Butadiene rubber insulated and sheathed tinned copper wire braided phase-shielded shielded flat flexible cable
YDGCB-VFRP
Nitrile insulated silicon rubber sheathed tinned copper wire braided phase-shielded shielded flat flexible cable
YDGCB-AF46RP
F46 insulated silicon rubber sheathed tinned copper wire braided phase-shielded shielded flat flexible cable spring loaded armored thermocouple
Five, Butadiene silicone flat cable code name meaning High temp thermocouple
Code
Code meaning
Y
Mobile series
DG
Silicone rubber insulation or sheath
VF
Nitrile insulation or sheath
B
Flat type
P
Copper wire (tinned copper wire) shielding
F46
Polytetrafluoroethylene propylene F46 Wear-resistant thermocouple
Note: The copper wire in the conductor core can be tinned.
Six Butadiene silicone flat cable main technical indicators
1. Finished cable conductor (R type) DC resistance (in accordance with GB3956);
2. The insulation resistance at 20 °C is not less than 100MΩ/KM;
3. The finished cable is subjected to AC 50HZ 3.5KV/5min voltage test without breakdown.